Whirlpool Dryer error codes

The codes people search for most, what each one means and what to check first. Tap a code for causes and step-by-step checks.

CodeWhat it means
AF
Check Vent, F4E3
Restricted airflow
The dryer sensed that air is not moving freely through the lint screen and vent. It keeps running, but clothes take longer to dry and lint buildup in a blocked vent is a fire risk.
F01
F:01
Main control board failure
The dryer's main electronic control failed its own self-check. This code appears mainly on older Duet and similar electronic dryers.
F22
F23
Exhaust thermistor fault (older Duet dryers)
On older Whirlpool Duet dryers, the control sees the exhaust temperature sensor as an open circuit (F22) or a short (F23). The dryer shuts off shortly after starting because it cannot monitor exhaust heat. Newer models report this as F3E1.
PFPower failure
Power to the dryer was interrupted during a cycle, or the control saw unstable voltage. The cycle stops until you restart it.
F1E1Control board error
The dryer's main control detected an internal problem with itself. The dryer may stop or refuse to start.
F3E1Exhaust temperature sensor problem
The dryer's exhaust thermistor, the sensor that reads air temperature leaving the drum, is giving a reading the control cannot use. Without it the dryer cannot regulate heat, so it stops the cycle.
F3E2Moisture sensor not reading
The dryer finished several loads in a row without its moisture sensor picking up any readings. Auto-dry cycles may run too long or stop early.
L2Low or no line voltage
The dryer is not getting the full supply voltage it needs to heat. The drum still turns, but clothes will not get hot or dry.